Thursday, February 1, 2024

Re: [electricboats] Recommendation for Charging 12v House Battery from 48v Bank

This is interesting.  So would this work?

I have a Lithium 100 amphr 48volt bank to run motor and a 48vlt 160amphr agm set which was original bank used for testing.

Can I use an 48 volt victron mppt controller to connect to the lithium set from an input from the Agm bank to help maintain the lithium or is there a better way to use the agm set?

The agm gets charged from a 48volt battery charger and soon a 48vlt 320w solar panel array.i can just ditch the agm but if i can use the extra capacity then this would be useful .....as long as I don't trash the lithium battery

Any help or ideas appreciated as always

Richard




On Wed, 31 Jan 2024, 08:04 Don & Ginny Workman, <tubadon@gmail.com> wrote:



On Jan 29, 2024, at 3:27 PM, Stew <stewart.reed@free.fr> wrote:

Makes total sense. Really helpful post, thanks. I currently run my 12V off the 48V bank but your solution ring-fences the 48V for motor energy. I think I'll do the same.
Stewart
+33 6 87 96 66 80

On 29 Jan 2024, at 17:43, Fabien Letourneau <fabien.letourneau@gmail.com> wrote:


I have a 48V battery bank and a 12V house.  Been running this setup for 4 years now and no issues.
I use an MPPT (Victron SmartSolar 100/20).  Connect your 48V battery to the MPPT PV input.  The MPPT sees your 48V or 52V bank as solar and it outputs proper charging voltage for your battery type.  You can set charge voltages, and all the charging parameters.  MPPT's are designed to do exactly that, so much better than a converter.  Chances are you already have a Victron unit for your solar arrays, if so you can use the same Victron Connect app to read the house battery unit as well.

Additional tip.  I charge the 48V bank at the dock (shore power) as well as solar when cruising (using another  MPPT).  To prevent our 12V loads discharging our 48V bank when at sea or dock and end up without a motor, we use a switch to the victron unit remote connector.  This is not very well documented or understood, but the VE. Direct connector can be used to turn the unit on or off without requiring the VE.Direct cable or unit.  Connect Pin 2 to GND will switch the MPPT charger off.  Switch that connection to open and the unit starts charging.

Keep in mind that the 48V whether connected through a DC-DC or MPPT, the 12V battery is being maintained all the time from your 48V hence draining your 48V bank, unless you have a 12V disconnect or a charger disconnect.  

In my case, at the dock, a relay opens when we have shore power, and allows the MPPT to charge the house battery.  When shore power is removed (when at sea), the relay closes and the MPPT for our 2V house is off.  We use minimal 12v loads and monitor the house battery level.  I also installed a bypass switch that I can manually through open if needed (after confirming sufficient reserve in the 48V bank).  So at sea, if the 12V is starting to get low, we flip the switch and the MPPT starts charging our house battery from our 48V.  Very nice and peace of mind, no worries about the house loads draining our 48V bank while sleeping, anchor light staying on, etc..