Here's my interpretation of the relevant ABYC standards.
E-11.16.1 Allows, but does not require, a DC grounding system to be installed.
E.11.16.25 If a DC grounding system is installed, it is allowed to be, but not required to be, combined with the lightning protection, cathodic bonding, and static electricity grounding systems.
E.11.5.4.7 Requires the AC system grounding bus to be connected to either the engine negative bus, or the DC main negative bus.
E.11.5.7.4 Allows, but does not require, the negative side of the DC system to be connected to be connected to ground.
TE-30 Requires that the propulsion electrical system remain isolated from the boat's grounding system.