On Wed, Dec 21, 2011 at 04:45:40PM -0000, Steve D wrote:
> I'm running Northstars and here's what the Design Engineer said.
>
> "I would recommend using a 2.45 vpc(14.7) bulk stage (176.4), a 2.35 vpc (14.1) absorption (169.2), and a float at our recommended 2.27 vpc(13.62)(163.44). Timing I would recommend is bulk for 4-5 hours, absorption stage for 6-8 hours, and then float settings. I would suggest engaging the bulk situation after a 40% DOD."
>
> I think that what ever the Manufacture says is the way to go. As you can see it all depends on the battery. Your flavor may very.

Right-oh; that sounds like a reasonable charge regime (although it's
missing the temperature-dependent changes; presumably, it's at the usual
60-whatever-degree reference temp.)

Thanks to the pointers from everyone here, and my own research with that
info as a starting point, I'm starting to feel like I'm getting a pretty
good picture of the region that AGMs operate in - i.e., I'm starting to
feel comfortable in having a "second sense" about whether something is
right or wrong in this regard. Thanks very much to everyone who
contributed to this thread - that's what I was looking for!

--