Hello Thomas, attached is a primitive sketch of my bms system 4 wires per box 16 total for bms I hope this helps. thank you kind regards Larry
On Friday, March 13, 2020, 06:08:17 AM PDT, THOMAS VANDERMEULEN <tvinypsi@gmail.com> wrote:
LARRY: I misunderstood. You're saying that your 12v boxes are 4s4p packs [16 cells per box], and that you've connected four of them in series to achieve the 51.2 nominal volts for the pack. That would mean the total number of cells in your full pack is 64. Do I have that right? Based on my limited knowledge of the subject, then, I would call that a 16s4p pack [16s x 3.2 = 51.2; 4p x 90Ah = 360Ah]. Do you run 16 leads out of your BMS, or are you monitoring on the individual cell level?