Tuesday, December 31, 2013

Re: [Electric Boats] RE: system questions

 

I sized and fused the cabling to suit the usage, not what could be derived from the batteries.
I have:
+ around 1700 ah at 48vdc battery  bank in 3 banks
+ have 3 Quattros 8 kw each hooked up in 3 phase
+ total system max amperage demand of 100 amps a bank.

So used single 16mm2 for all confections within banks and 2x16mm2 welding flex (2 @ positive and negative) from each back to dc distribution point maximum run 5 metres, fused 200 amp.
Although a single 16mm should and did handle 100 amps easily over a lousy 5 metres, and despite getting barely warm (it was probably me holding them that made them warmer) there was a 1 volt drop difference between 1 and 2 using a single 16mm welding flex.
So on the belts and braces principle I used fig 2 hookup and doubled up the 16mm output from each bank and I'm not sure I can see any built drop especially as the Quattros and then the VSDs controlling the 3 phase motors have an adjustable ramp up/soft start facility.

Logically the figure 2 hookup must give better current flow within and from a bank.
I was the national service manager for a large pump company for years and the  electrical to water flow,  resistance to fiction analogy works in most situations and would be borne out here you'd think.

On 30 Dec 2013 13:36, "Roger L" <rogerlov@ix.netcom.com> wrote:
 

"I tested fig 1 against 2 and the difference was huge."
 
Interesting....and the difference in hoop up schemes has to become even more important as the connecting wire diameter goes down. Just curious: what size copper are you using?
  Roger L.
 
----- Original Message -----
Sent: Monday, December 30, 2013 1:06 AM
Subject: Re: [Electric Boats] RE: system questions

Hi

I have my 24 blocks, (4 in series then 2 of those in parallel, then 3 of those in parallel as I have 3 boxes of eight) hooked up as per fig 2.
I tested fig 1 against 2 and the difference was huge. Didn't bother with anything more complicated.
I have been told by two marine electricians and a solar installer that fig 1 type is good enough for 9 out of 10 situations, which is a real worry. Especially as fig 2 is so easy to do.
It does make you wonder about guys who "do this for a living".

Cheers

On 29 Dec 2013 17:03, "Roger L" <rogerlov@ix.netcom.com> wrote:
 

Nice article, Julian. I agree. Reading through it, we can see at a glance - once you tumble to the initial idea - (and isn't that always the truth of things....it's easy once you see it).  Anyway, near as I can tell, it looks like SmartGauge's way of hooking up the batteries to balance lead resistance is also the theoretically correct way to balance the battery drain.
 
And even though his theory checks with my own understanding, I was surprised to see how large the difference was... in spite of his using huge, short copper wire for leads between batteries.
I mean....who really uses huge 1 3/8" diameter stranded copper wire for their battery interconnecting cables? And who consistently keeps the length to be exactly 8" each? 
It's nice that he gives the constants that he uses. I also agree that even if the theory checks, the magnitude of the difference is surprisingly large. Someone should check on his figures just for a "reality check. Be easy enough to do it in a spreadsheet.  
 
Hmmm....it occurs to me that there's a quick arithmetic check possible and the advantage is that it uses the numbers that SmartGauge is reporting. Since the unbalanced batteries in Fig 1 and the balanced drain configuration in Fig 2 requires the use of slightly more cable in Fig 2 as he drew it., then the sum of currents in Fig2 should be higher as well.  
That only works because he is using a constant .02 ohms in the calculations (for each internal battery resistance).
 
So....by using his own numbers to check - and assuming that his wiring calcs match his sketch - the sum of the drain in Fig 2 should be MORE than the sum of Fig 1 by some small amount simply because the wires are longer.
 
Fig1 Sum = 35.9+26.2+20.4+17.8 = 100.3 amps
Fig2 Sum = 26.7+23.2+23.2+26.7 = 99.8 amps
 
Oops....Hmmm....it doesn't check!! Did I copy something wrong?  No....apparently not. What's going on here?
Still, if I was putting batteries in parallel I'd wire in keeping with Fig2. Betting that's pretty much the standard for batteries in parallel. 
    Roger L.     F-28cc 
 
----- Original Message ----- From: Julian Webb
Sent: Sunday, December 29, 2013 2:49 AM
Subject: Re: [Electric Boats] RE: system questions

Hi

While 48 volts makes built drop less of an issue than 12 or 24 volts, it's still incredibly important especially as the current goes up.
I have a 48 built system with 24 x 220ah blocks and we serised/paralleled them up two different ways just to check and were stunned at the difference, and I'm almost ashamed to admit I've worked in the  electrical industry for years BUT as the attached article says when you're used to working with 110/220 it's seldom an issue.
Armchair experts will tell you "what difference can it make", please read the attached article and remember that theory is where you should start but practice I'd where you must finish so listen to both. Cheers

On 29 Dec 2013 08:24, "Sheya" <sheyagiggles@yahoo.com> wrote:
 

Hey Mike,
Thanks for the response. I believe that since we have 8 (12V 200AH blocks) that would mean we have a total of 400AH at 48V. Would you agree thats right? We would have 2 blocks of 4 in series and those 2 blocks connected in parallel, does that make sense?
Sheya and Jason


From: "mike@electricyachtssocal.com" <mike@electricyachtssocal.com>
To: electricboats@yahoogroups.com
Sent: Friday, December 27, 2013 6:45:01 AM
Subject: [Electric Boats] RE: system questions

 
I am surprised no one has responded to your inquiry and hope this will stimulate others.  I know of at least two conversions of heavy displacement Morgan 41s by members of this group and they should have good advice for you.  I believe this is the proposed system and your usage:
 
The motor is a continuous rated 15hp that is to say 11,200 continuous rated and likely about 12hp to the shaft.  The boat is a Morgan 41 which often was supplied with a 45hp motor that likely drove at peak 30hp to the shaft.
The battery size is 200AH at 48v
You are looking to sail the boat as far as Alaska from your BC location. 
This is what our computer projection says and I would encourage all vendors to share your projections for this boat. 
Speed & Power
Kts-Watts
2.3-480
2.9-960
3.6-1920
4.6-3840
5.3-5760
5.8-7680
6.4-12480
6.8-17760
Hull speed 7.93
Your motor should push the boat at about 6.2kts in calm and likely about 4.5 in a mixed sea state and about 3kts against a poor sea state.  The 200AH battery bank will push the boat at an 80% dod for about 22NM at 3kts and 14NM at 4kts.
Mike
Electric Yacht of Southern California


__._,_.___
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (12)
Recent Activity:
.

__,_._,___

Monday, December 30, 2013

[Electric Boats] Re: Charging my battery bank

 

How about sailing the boat while the motor is engaged? May need some fine tuning and tweaking but a motor turning over should generate a current. Also recommend a solar panel or two on the boat at least when you come on board after a period it will have been fully charged. Neither of these will be fast charges but free and green. if you mainly sail your boat this should help with range and economy. Can't help with the fine details of battery management systems but there is lots of good information on this site that should help.

--- In electricboats@yahoogroups.com, <luke.wolbrink@...> wrote:
>
> Hello all,
>
>
> I'm in the process of converting my sailboat to electric. I've got just about everything worked out with the exception of charging. I'm purchasing individual 48v 20ah lifepo4 batteries to make up a 100ah bank. How do I go about charging them? Each battery has bms so can I just hookup a single high output charger and let each battery's BMS take care of when to charge and not? Alternately do I hookup 5 individual chargers that are sized to the individual batteries? How do I isolate in that case? A diagram and suggested chargers would be most helpful.
>
>
> thanks
>

__._,_.___
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (3)
Recent Activity:
.

__,_._,___

[Electric Boats] Generating electricity from an electric motor while sailing

 

I am no expert on electric motors and power. My basic understanding is that turning over an electric motor can produce electricity. I realise is can be a complex business - depending on whether the motor is induction, brushed etc, AC or DC, the revs and gearing needed etc.

Pretty useful thing for sail boats though, using an existing electric motor to be able to charge batteries while under sail.

I have a Farrier F-31 (see www.fleetwing.com.au) which I only motor in and out of dock or on the rare occasion when there is no wind here in Tasmania. I much prefer to sail. This trimaran has different characteristics to a monohull (greater range of speed and less tolerance of weight). This sort of battery charging configuration would especially suit a monohull where batteries could provide very useful ballast down low in the boat, and where speed has a lesser range.

I have not been able to find any posts on this topic yet, can anyone help?

Cheers,

Chris Wilson
Abels Bay, Tasmania

__._,_.___
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (1)
Recent Activity:
.

__,_._,___

Re: [Electric Boats] RE: Tartan 30 Sailboat

 

Mike,

Actually, it would be good for all of us (vendors) to get together and create a comparison table of the various systems showing ratings, weights, features, options etc. I would be able to supply info for the Thoosa & Triton systems from Clean eMarine. I could also supply info for the Oceanvolt saildrives. 

It would also be good to compare all of our systems against the diesel engines and show the advantages of the electric propulsion since diesel is our real competitor.

Your thoughts?



On Mon, Dec 30, 2013 at 7:28 AM, <GNHBus@aol.com> wrote:
 

Mike, 


Can you please advise the Benefits/Value of the Elco System over any other Vendor designed/supplied System. There are a lot of folks coming to this forum looking for advice and I don't think there has been a thread on this subject. If there has been, I apologize for the repetition.

Regards
GNHBus


__._,_.___
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (4)
Recent Activity:
.

__,_._,___

Re: [Electric Boats] RE: system questions

 

"I tested fig 1 against 2 and the difference was huge."
 
Interesting....and the difference in hoop up schemes has to become even more important as the connecting wire diameter goes down. Just curious: what size copper are you using?
  Roger L.
 
----- Original Message -----
Sent: Monday, December 30, 2013 1:06 AM
Subject: Re: [Electric Boats] RE: system questions

Hi

I have my 24 blocks, (4 in series then 2 of those in parallel, then 3 of those in parallel as I have 3 boxes of eight) hooked up as per fig 2.
I tested fig 1 against 2 and the difference was huge. Didn't bother with anything more complicated.
I have been told by two marine electricians and a solar installer that fig 1 type is good enough for 9 out of 10 situations, which is a real worry. Especially as fig 2 is so easy to do.
It does make you wonder about guys who "do this for a living".

Cheers

On 29 Dec 2013 17:03, "Roger L" <rogerlov@ix.netcom.com> wrote:
 

Nice article, Julian. I agree. Reading through it, we can see at a glance - once you tumble to the initial idea - (and isn't that always the truth of things....it's easy once you see it).  Anyway, near as I can tell, it looks like SmartGauge's way of hooking up the batteries to balance lead resistance is also the theoretically correct way to balance the battery drain.
 
And even though his theory checks with my own understanding, I was surprised to see how large the difference was... in spite of his using huge, short copper wire for leads between batteries.
I mean....who really uses huge 1 3/8" diameter stranded copper wire for their battery interconnecting cables? And who consistently keeps the length to be exactly 8" each? 
It's nice that he gives the constants that he uses. I also agree that even if the theory checks, the magnitude of the difference is surprisingly large. Someone should check on his figures just for a "reality check. Be easy enough to do it in a spreadsheet.  
 
Hmmm....it occurs to me that there's a quick arithmetic check possible and the advantage is that it uses the numbers that SmartGauge is reporting. Since the unbalanced batteries in Fig 1 and the balanced drain configuration in Fig 2 requires the use of slightly more cable in Fig 2 as he drew it., then the sum of currents in Fig2 should be higher as well.  
That only works because he is using a constant .02 ohms in the calculations (for each internal battery resistance).
 
So....by using his own numbers to check - and assuming that his wiring calcs match his sketch - the sum of the drain in Fig 2 should be MORE than the sum of Fig 1 by some small amount simply because the wires are longer.
 
Fig1 Sum = 35.9+26.2+20.4+17.8 = 100.3 amps
Fig2 Sum = 26.7+23.2+23.2+26.7 = 99.8 amps
 
Oops....Hmmm....it doesn't check!! Did I copy something wrong?  No....apparently not. What's going on here?
Still, if I was putting batteries in parallel I'd wire in keeping with Fig2. Betting that's pretty much the standard for batteries in parallel. 
    Roger L.     F-28cc 
 
----- Original Message ----- From: Julian Webb
Sent: Sunday, December 29, 2013 2:49 AM
Subject: Re: [Electric Boats] RE: system questions

Hi

While 48 volts makes built drop less of an issue than 12 or 24 volts, it's still incredibly important especially as the current goes up.
I have a 48 built system with 24 x 220ah blocks and we serised/paralleled them up two different ways just to check and were stunned at the difference, and I'm almost ashamed to admit I've worked in the  electrical industry for years BUT as the attached article says when you're used to working with 110/220 it's seldom an issue.
Armchair experts will tell you "what difference can it make", please read the attached article and remember that theory is where you should start but practice I'd where you must finish so listen to both. Cheers

On 29 Dec 2013 08:24, "Sheya" <sheyagiggles@yahoo.com> wrote:
 

Hey Mike,
Thanks for the response. I believe that since we have 8 (12V 200AH blocks) that would mean we have a total of 400AH at 48V. Would you agree thats right? We would have 2 blocks of 4 in series and those 2 blocks connected in parallel, does that make sense?
Sheya and Jason


From: "mike@electricyachtssocal.com" <mike@electricyachtssocal.com>
To: electricboats@yahoogroups.com
Sent: Friday, December 27, 2013 6:45:01 AM
Subject: [Electric Boats] RE: system questions

 
I am surprised no one has responded to your inquiry and hope this will stimulate others.  I know of at least two conversions of heavy displacement Morgan 41s by members of this group and they should have good advice for you.  I believe this is the proposed system and your usage:
 
The motor is a continuous rated 15hp that is to say 11,200 continuous rated and likely about 12hp to the shaft.  The boat is a Morgan 41 which often was supplied with a 45hp motor that likely drove at peak 30hp to the shaft.
The battery size is 200AH at 48v
You are looking to sail the boat as far as Alaska from your BC location. 
This is what our computer projection says and I would encourage all vendors to share your projections for this boat. 
Speed & Power
Kts-Watts
2.3-480
2.9-960
3.6-1920
4.6-3840
5.3-5760
5.8-7680
6.4-12480
6.8-17760
Hull speed 7.93
Your motor should push the boat at about 6.2kts in calm and likely about 4.5 in a mixed sea state and about 3kts against a poor sea state.  The 200AH battery bank will push the boat at an 80% dod for about 22NM at 3kts and 14NM at 4kts.
Mike
Electric Yacht of Southern California


__._,_.___
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (11)
Recent Activity:
.

__,_._,___

[Electric Boats] RE: Tartan 30 Sailboat

 

Mike, 


Can you please advise the Benefits/Value of the Elco System over any other Vendor designed/supplied System. There are a lot of folks coming to this forum looking for advice and I don't think there has been a thread on this subject. If there has been, I apologize for the repetition.

Regards
GNHBus

__._,_.___
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (3)
Recent Activity:
.

__,_._,___

Re: [Electric Boats] RE: new to the group [1 Attachment]

 
[Attachment(s) from Julian Webb included below]

Gerry

If your calcs are OK with $10k a year fuel and your recharges are free as you are using hydro for power, simplistically all you need do is figure out if you can use a system that when you amortise the batteries out over their life of the yearly cost is the same or under $10k a year. Even thrashed AGMs with a three year life will give you more than that.
One you factor  environmental considerations and the fact that  replacement battery costs will drop over the same period I can't see the problem.
Getting a true non theoretical hull speed/power figure is a good start, so use the old spring balance tow method and you'll have that in no time.
In your situation you must get some fact into the equations and I think the best place to start is with your own hull power requirements.
I attach an old but down to earth, simple and above all else practical approach from someone who was in the businesses and had lots of proof of his own hard work. Sorry the file or so big but it's worth it.

Cheers

On 29 Dec 2013 20:34, "The Boys" <theboyfam@gmail.com> wrote:
 

Thank you Mike

The boat I am working with now is the Red Wing 23 from CMD it is a flat bottom  displacement  hull  lwl 21'  beam wl 6'6"  7'10" overall, dr 1'6" the designer says on the web site that she should get about 6-8 kts from a 15hp gas outboard. I plugged the lines roughly into delftship and it gave me a hull resistance of 110 lbs at 8 kts and 65 lbs @ 6 kts with a displacement of around 1.5 tons depending how she would be loaded of course.
 I will be fitting her with a box keel and am leaning toward inboard power I hope to be able to swing a prop in the range of 3x14x11 or so at about 1200rpm max @shaft (2:1). as the box keel will get my shaft a little lower in the water for the larger wheel.
I had been considering an ME 5kw motor @ 48v like the ME1117 
I am also intrigued by the Agni 95 which seems to be capable of powering this boat at 1:1 @24v  around 100 amps
My high hopes are for 5-6 kt cruise, hull speed should be around 6.3 I think. I would hope for 3 hrs at cruise in order for the boat to be useful here.
In summer we will use it for supporting canoes on our outdoor adventure program. I hope to be able to run at 2kts for most of the day using solar on multi day trips.

The semi displacement boat is just an Idea and more of a light displacement concept than semi.It would replace one of our planing supply/commutor/watertaxi boats. The Idea is: if it is possible to get a vessel capable of carrying 12 adults to cruise at 10 kts for 3 hr/day in 1.5 hr runs we could save up to $10 000/ year in fuel. 
I was thinking something around 30' x 7' at the waterline built as light as possible to keep the displacement way down like 3000lbs, spartan shelter and benches ect. according to Gerr's  d/l ratio this light narrow hull should have a hull speed of 13kts and would need 53 diesel horses to get it to 10kts.
do you know if anyone has tried some thing like this? The propeller calculator at Vic Prop says that a 60 hp diesel will get this hull to 10 kts using 15 hp spinning a 3x16x15 prop.with a max output of 53 hp@shaft and 172ft lbs@ shaft (2:1 reduction) giving a full out speed of over 15 kts.
I would love to weigh these theoretical numbers with some real life experience.
I know that not many boats like this are around though other than 1930's rumrunners and old style lobsterboats or boats like Nigel Irens'  Rangeboat or his own boat Greta. 

I would be interested in any info or advise on either or these boats Especially the first one as it is real and in the shop right now. I hope to get the students involved next school year. but I will be starting and organizing the project until then.

Thank you 
Merry Christmas and Happy New Year

Gerry


On 2013-12-27, at 6:15 AM, <mike@electricyachtssocal.com> <mike@electricyachtssocal.com> wrote:

 

Gerry,
Vendor alert.  Welcome to the user group.  The semi displacement hull is not as effecient at slow speeds as the full displacement hulls that most of us on this website talk about.  There are several with good working knowledge such as the Arc.  We are starting to see a growing interest in electric propulsion by the power boat market but most are unreasonable expectations.  You can not push a 20000 pound sportfisher with an electric motor at 10kts but you can do some reasonable smaller runabouts and service boats at speeds in the 5 to 8kts.  I am sure the other vendors that visit this site will also give you expert advice.   We are all dealing with the same physics and the power to push a boat will be the same for all of the systems within a reasonable amount.  System design and engineering will also play a part in the effeciency.

To give you an expectation that is reasonable, think in terms of what you know about the current propulsion system.  This is including the motor, the propeller and the hull.  If you have a 50hp gas/diesel motor pushing the boat today that meets your needs of displacement speed and reliability in your environment, than it is reasonable to look at electric systems from several vendors. Share the following information and I am sure several vendors will respond:
Length at Waterline
Beam
Displacement (include passenger loads)
Propeller
and finally speeds at current propeller RPM would be helpful to know.

We wish you the best with your mission and works.
Regards, Mike
Electric Yachts of Southern California


__._,_.___